Quidel/Lyra Influenza A+B Assay/M106/10 reactions
其他試劑盒
商品編號(hào)
M106
品牌
Quidel
公司
Quidel,inc.
公司分類(lèi)
Influenza
Size
10 reactions
商品信息
Description:
Quidel
Molecular Influenza A+B Control Set
Features & Benefits:
The Lyra Influenza A+B Assay is a multiplex real-time RT-PCR assay for the qualitative detection and identification of viral nucleic acids extracted from nasal swabs and?nasopharyngeal swabs specimens. The real-time influenza test has been shown to detect HIN1, H3N2 and H7N9 subtypes but does not differentiate the subtypes from Influenza A.
A multiplex RT-PCR reaction is carried out under optimized conditions in a single tube generating amplicons for each of the target viruses present in the sample. Identification of influenza A occurs by the use of target specific primers and a fluorescent-labeled probe that hybridizes to a conserved region within the matrix protein gene. Identification of influenza B occurs by the use of target specific primers and fluorescent-labeled probes that hybridize to a conserved influenza B sequence within the neuraminidase gene.
The Lyra Influenza A+B Assay has a one-step reagent set up. Test results are available in less than 75 minutes after extraction. Lyra Influenza A+B RT-PCR is available for use on the
Applied Biosystems
?
7500 Fast Dx Real-Time PCR Instrument, QuantStudio
TM
Dx Real-Time PCR Instrument and Cepheid
?
SmartCycler
?
II.
The Lyra Influenza A+B Assay is one in a growing menu of assays and is intended to aid in the differential diagnosis of influenza A and/or influenza B viral infections in humans.
Feature
Benefit
One-step reagent set-up
Rehydration solution is simply added to the lyophilized Master Mix
Speed
Results in less than 75 minutes after extraction
Easy training
Simplified and uniform workflow with standard pipetting volumes
Refrigerated storage
No freezer needed. 2°C to 8°C storage
Long shelf life
2 years from date of manufacture
Room temperature set up
No ice or cooling block required
Flex
IBL
e 96-test format
Kit includes vials of 12x8 Master Mix, Rehydration Solution and liquid Process Controls
Multi-well multiplex panels
Standardized
Thermo
cycling conditions for the respiratory assays allow for multiple analytes to be analyzed on the same plate from the same extracted specimen, effectively providing a customizable panel of results
Product Specifications:
Product Spec Name
Product Spec Data
Sample type
Nasal swab, Nasopharyngeal swab
Time to results
Less than 75 minutes after extraction
Reagent storage conditions
2°C to 8°C
Controls storage conditions
2°C to 8°C
Positive Percent Agreement*
A: 100%; B: 98.4%
Negative Percent Agreement*
A: 98.7%; B: 95.5%
LOD
2 to 100 TCID
50
/mL
Sample volume needed for extraction
180 ?L
Purified nucleic acid volume needed to testing
5 ?L
Shelf life
24 months
*Refer to Package Insert for additional performance claims.
?
產(chǎn)品貨號(hào):待定